SO-A12 Galvanometer Scanner
Applications:
Marking, Processing-on-the-fly, Micromachining, Engraving
SO Standard galvanometers are designed with analog and digital interfaces, the products of this series are various. They have the characteristics of zero drift, higher speed, lower temperature and stronger anti-interference, etc.
They can be widely used in different industrial applications including precision laser marking, laser cutting, laser welding, laser drilling, rapid photographing and science researches, etc.
Motor Specification
|
Working Temperature
|
25℃ ±20℃
|
Linearity
|
99.9%
|
Setting Time
|
≤ 0.4ms
|
Scale Drift
|
< 20PPM/℃
|
Zero Drift
|
< 10μRad. /℃
|
Long Term Drift Over 8 hours
|
< 0.5mRad
|
RMS Current
|
3A(Max)
|
Peak Current
|
15A(Max)
|
Maximum Scan Angle
|
± 20°
|
Storage Temperature
|
-10 to +60℃
|
Resolution
|
10μrad
|
Repeatability
|
12μrad
|
Input Aperture
|
12mm
|
Frequency
|
≤800Hz
|
Serve Driver Board Specification
|
Input Voltage
|
± 15/24VDC@4AMAX.RMS
|
Interface Signals
|
Digital:XY2-100
|
Analog Signal Input Resistance
|
200K ± 1%Ω
|
Position Signal Input Resistance
|
1K ± 1%Ω
|
Position Signal Input Scale Factor
|
0.5V/°
|
Position Signal Output Scale Factor
|
0.5V/°
|
Working temperature
|
0℃ -40℃
|
|